Get complete information related to latest Flow Transducer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Flow Transducer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Flow Transducer Tenders.
Tender For design, manufacture, supply, installation, commissioning, prove out of computerized axle journal & seat, wheel id and bearing id-od size verification & integrated data recording system along with essential spare as per technical specification no. mfg./009/size verification/2025 at annexure-b with 3-year post warranty camc.
Tender For supply of 220v smps based float-cum-boost charger for chp mcc-1 nr crusher house as per technical specification. rating shall be 80a or as per load cycle min rating of 220ah whichever is higher. , ni-cd battery health monitoring system for chp mcc-01 near crusher house , one for each set of battery as per technical specification , 220v smps based float-cum-boost charger for chp mcc-2 nr bunker mcc as per specification.rating shall be 40a or as per load cycle min rating of 120ah whichever is higher. , ni-cd battery health monitoring system for chp mcc-2 nr bunker mcc one for each set of battery as per technical specification , 220v smps based float-cum-boost charger for ahp mcc-1 nr main plant as per specification.rating shall be 60a or as per load cycle min rating of 150ah whichever is higher. , ni-cd battery health monitoring system for ahp mcc-1 nr main plant one for each set of battery as per technical specification. , battery fuse box for chpmcc1 area minimum 50a as per boq in technical specification , battery fuse box for chpmcc2 area minimum 25a as per boq in technical specification , battery fuse box for ahpmcc1 area minimum 40a as per boq in technical specification , discharge resistor for chp mcc-1 area with shunt suitable for 5 hour discharge rate suitable for 220ah nicad battery , discharge resistor for chp mcc-2 area with shunt suitable for 5 hour discharge rate suitable for 120ah nicad battery , discharge resistor for ahp mcc-1 area with shunt suitable for 5 hour discharge rate suitable for 150ah nicad battery , mandatory spares for float cum boost charger as per annexure-iii , commissioning spares for float cum boost charger as per annexure-ii , lump sum charges per visit for engineer , except daily charges , lump sum daily charges for engineer bid number/ & ( * ) : gem/2025/b/6153209 dated/ + : 25-04-2025 bid document/ 2 2 1 / 28
Tender For supply of supply of air cooled floor mounted package air conditioner having cooling capacity q -48 kw min air flow rate 11000 cmh min and pressure head 400 pa min as per attached technical specification , supply of air cooled floor mounted package air conditioner having cooling capacity q-24.3 kw min air flow rate 4080 cmh min as per attached technical specification , supply of air cooled floor mounted package air conditioner having cooling capacity q-32 kw min air flow rate 7000 cmh min and pressure head 600 pa min as per attached technical specification , supply of air cooled floor mounted package air conditioner having cooling capacity q- 10.92 kw min air flow rate 6300 cmh min and pressure head 600 pa min as per attached technical specification , supply of air cooled floor mounted package air conditioner having cooling capacity q-16 kw min air flow rate 4000 cmh min and pressure head 400 pa min as per attached technical specification , supply of air cooled floor mounted package air conditioner having cooling capacity q-45 kw min air flow rate 9000 cmh min and pressure head 500 pa min as per attached technical specification , supply of ceiling mounted ductable idu unit of cooling capacity 3 tr air cooled including additional 5 meter copper tube length liquid , supply of split system with suspended sub ceiling idu of cooling capacity 4 tr min air cooled odu unit including additional 5 meter copper tube length liquid
Tender For corrigendum : supply of operational and technical equipment - nvg monoculars , dmr radio vhf handheld sets along with spare batteries , rfid timing system high accuracy , remote audio monitoring system roip , portable wireless projectors for outdoor training classes , bodyworn cameras , docking station for body worn cameras , vhf repeater equipment with accessories , digitalization of audio system for multipurpose training hall , audio system for command and control , lightening suppression system with accessories , 55 inch tvs for media surveillance , stabilizer 10kva , voice recorder , fax machine , equipment cooling system
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s
Tender For a/r & m/o external water supply and sewerage system at afs hindan, ghaziabad during 2025-26 (sh: providing essential services to attend day to day complaints in domestic & technical area).